• AT181G-CT-4G Three-Phase Multifunction 4G Meter
  • AT181G-CT-4G Three-Phase Multifunction 4G Meter
  • AT181G-CT-4G Three-Phase Multifunction 4G Meter
  • AT181G-CT-4G Three-Phase Multifunction 4G Meter
  • AT181G-CT-4G Three-Phase Multifunction 4G Meter
  • AT181G-CT-4G Three-Phase Multifunction 4G Meter
AT181G-CT-4G Three-Phase Multifunction 4G Meter
AT181G-CT-4G Three-Phase Multifunction 4G Meter
AT181G-CT-4G Three-Phase Multifunction 4G Meter
AT181G-CT-4G Three-Phase Multifunction 4G Meter
AT181G-CT-4G Three-Phase Multifunction 4G Meter
AT181G-CT-4G Three-Phase Multifunction 4G Meter
+

Energy Meter Series

AT181G-CT-4G Three-Phase Multifunction 4G Meter


Application: Photovoltaic Inverter System Charging station infrastructure Wind Power System Power System Utilities / Future Communities SCADA / Energy Management System

Product Details


Application:


Photovoltaic Inverter System
Charging station infrastructure
Wind Power System 
Power System Utilities / Future Communities
SCADA / Energy Management System

 

Functions

  • Bidirectional active/reactive energy metering (forward/reverse)
  • Real-time measurement of voltage, current, and power
  • Demand measurement and peak demand recording
  • Multi-tariff (4 rates, 8 time periods; optional)
  • 4G communication
  • Strong electromagnetic compatibility, suitable for industrial environments;
  • Three-phase, four-wire full-parameter measurement (U, I, P, Q, S, PF, F);
  • LCD display with local cyclic display or manual page turning;
  • DIN-rail mounting to save space in switchgear;
  • High insulation and withstand voltage, safety class CAT III

 

Parameters

 

Input voltage

Rated Voltage

230 VAC(phase voltage) / 400 VAC(line voltage)

Direct access

Measurement range: 176–276 VAC

Measuring frequency range

45~65 Hz

 

Input current

CT Primary side range

1~9999 A

CT Secondary Side Output

Ratings: 1A/5A (default), 100mA/mV (optional)

 

Pulse power output

Output Mode

Open-collector optocoupler pulses

Pulse Frequency

Can be set to: 0.001, 0.01, 0.1, or 1 kWh/kvarh per pulse

Pulse Width

Can be set to: 60, 100 (default), or 200 ms

Pulse Output Type

Can be set to: Forward/Reverse/Total Active or Reactive

Output Level

Class A, in accordance with IEC 62053-31

Input Voltage

5–27 VDC

Communication

4G

Accuracy

Voltage/Current

Class 0.5

Active power

Class 0.5

Reactive power

Class 2

Apparent power

Class 1

Active power

Class 0.5S

Reactive power

Class 2

Power factor

Class 1

Frequency

Class 0

 

Dimension

 

 

Wiring 3P4W

 

 

Related Products

ATZ3000 Multi-function Power Analyzer

ATZ2000 Multi-function Power Analyzer

ATZ1000 Multi-function Power Analyzer

AT100G Single Phase Din Rail Energy Meter

Online Message

Leave your information, and we will contact you as soon as possible.