• ATW002 Bracelet Passive Temperature Sensor
  • ATW002 Bracelet Passive Temperature Sensor
  • ATW002 Bracelet Passive Temperature Sensor
  • ATW002 Bracelet Passive Temperature Sensor
ATW002 Bracelet Passive Temperature Sensor
ATW002 Bracelet Passive Temperature Sensor
ATW002 Bracelet Passive Temperature Sensor
ATW002 Bracelet Passive Temperature Sensor
+

Wireless Temperature Monitoring Device

ATW002 Bracelet Passive Temperature Sensor


Application: Temperature monitoring of power switchgear (high-current cabinets such as main transformer feeder cabinets and interconnection cabinets) Moving contact points on circuit breakers, isolating switches, and similar equipment (contacts, connectors, etc.) Connection points of current transformers (CTs) inside cabinets (to prevent overheating caused by poor contact) Critical points in power equipment such as busbars and cable joints Applications requiring early detection of potential equipment overheating to prevent failures caused by abnormal temperatures

Product Details


Application:

 

  • Temperature monitoring of power switchgear (high-current cabinets such as main transformer feeder cabinets and interconnection cabinets)
  • Moving contact points on circuit breakers, isolating switches, and similar equipment (contacts, connectors, etc.)
  • Connection points of current transformers (CTs) inside cabinets (to prevent overheating caused by poor contact)
  • Critical points in power equipment such as busbars and cable joints
  • Applications requiring early detection of potential equipment overheating to prevent failures caused by abnormal temperatures

 

Functions

 

  • Real-time Temperature Monitoring: Temperature signals are collected every 10 seconds to monitor equipment node temperatures in real time
  • Active Alarms: Triggers an alarm when temperature changes exceed 2°C (alarm threshold is configurable)
  • Power Supply Voltage Self-Check: The sensor continuously monitors its own power supply voltage to ensure proper operation
  • CT Inductive Power Supply: Power is supplied via an induced current (start-up current: 5A), requiring no batteries or external power source
  • Wireless Remote Transmission: 433MHz RF, with a transmission range of up to 300 meters in open areas
  • Easy Installation: Strap-on installation requires no drilling and does not alter the device’s insulation structure
  • High-Temperature-Resistant Materials: The housing and straps are made of high-temperature, flame-retardant silicone; IP50 protection rating

 

Parameters

 

Temperature Measurement Range

-40°C to +125°C (customizable up to 200°C)

Resolution

0.1℃

Measurement Accuracy

±1℃

Sampling interval:

Default: 10 seconds (customizable)

Reporting interval:

Default: 2 minutes (customizable)

Alarm threshold:

Default: 2°C (customizable)

RF frequency:

433 MHz

Transmission range:

300 meters (open area)

Power supply:

CT Inductive Power Extraction (Inductive Current ≥ 5A)

Service life:

10 years

Installation method:

Strap-on design (secured with nylon cable ties and rubber rings)

Housing/strap material:

High-temperature flame-retardant silicone

Protection rating:

IP50

Dimensions:

44.5 mm × 37 mm × 24.5 mm (strap length: 360 mm)

Weight

About 50 g

 

Dimension

 

 

Logic diagram

 

Related Products

ATW001 Bracelet with Active Temperature Sensor

ATZ3000 Multi-function Power Analyzer

ATZ2000 Multi-function Power Analyzer

ATZ1000 Multi-function Power Analyzer